Zanran
✓ Graphs ✓ Tables ✓ Reports
 
Format: www.xyz.com or *.gov
Where ▼
Where ▲
Date:
Note: Results will be PDF and Excel – which we can date reliably. For PDFs, it will either be the date the PDF was creater, or the date visible in the graph or chart.
When ▼
When ▲
What ▼
What ▲

AND, OR, NOT in upper case control boolean queries, in lower case they are just words.

Data & statistics on Maximum Allowable Emission Rates in lb per hr and ton per y – 11346 results

Hover over me
PM10 Emissions Emission Factor (uncontrolled) = 8.16 lb/MMBtu Emission Factor (controlled) = 0.012 lb/MMBtu (permit condition) Calculations: 0.012 lb/MMBtu * 4013 MMBtu/hr = 48.2 lb/hr (short-term value) 0.012 lb/MMBtu * 3737 MMBtu/hr = 44.8 lb/hr (long-term average value) 44.8 lb/hr * 8760 hr/yr * 0.0005 ton/lb = 196.4 ton/yr (annual limit)
330 more results from this site ▶

PM10 Emissions Emission Factor (uncontrolled) = 8.16 lb/MMBtu Emission Factor (controlled) = 0.012 lb/MMBtu (permit condition) Calculations: 0.012 lb/MMBtu * 4013 MMBtu/hr = 48.2 lb/hr (short-term ...

www.deq.state.mt.us/AirQuality/ARM_Permits/3182-01.pdf

Primary Fuel Feed Rate = 202 ton/hr Maximum Short Term Heat Input to Boiler = 4013 MMBtu/hr Maximum Long Term Primary Fuel Feed Rate = 188 ton/hr Maximum Long Term Heat Input to Boiler = 3737 MMBtu/hr Sorbent Feed Rate = 10, 332 lb/hr (45, 255 ton ...
IV. Emission Inventory PM10 (tpy) SO2 (tpy) NOx (tpy) VOC (tpy) HAPs (tpy) Source CO Pb (tpy) (tpy) Main Boiler #1 (MP-1) Main Boiler #2 (MP-2) Auxiliary Boiler #1 (AB-1) Auxiliary Boiler #2 (AB-2) Backup Generator (BG-1) Coal Handling Lime

Dec 2005 | Montana Department of Environmental Quality (DEQ – 330 more results from this site
Original Url: http://www.deq.state.mt.us/AirQuality/ARM_Permits/3182-01.pdf
Pyrolysis Oven Emissions NOx lb/hr TPY lb/hr TPY
268 more results from this site ▶

Pyrolysis Oven Emissions NOx lb/hr TPY lb/hr TPY

www.deq.state.ok.us/apps/nondiv/permitspublic/storedpermits/2699.pdf

are for burning 100% plastic at a maximum charge rate of 10 lb/hr of combustible materials ...
Controlled VOC emissions = (1 – 90% control) * 2, 317, 186 lb/yr / 2, 000 lb/ton = 115.86 TPY VOC emissions from the ink blending room were estimated at 0.50 lb/hr and 2 ...
Pyrolysis Oven Emissions NOx lb/hr TPY lb/hr TPY Emission Unit Pyro. Oven PM10 lb/hr TPY VOC lb/hr TPY SO2 CO lb/hr TPY Total Facility Emissions PM10 NOx SO2 VOC Ozone lb/hr TPY lb/hr TPY lb/hr TPY lb/hr TPY lb/hr TPY lb/hr TPY CO EXISTING

Jan 2014 | Welcome to the Oklahoma Department of Environmental Quality – 268 more results from this site
Original Url: http://www.deq.state.ok.us/apps/nondiv/permitspublic/storedpermits/2699.pdf
Dillon Wood Boiler1 32 MMBtu/hr, 20,000 tons/yr wood, 4400 Btu/lb, 550,000 dscf/hr, 5500 hr/year at max capacity NOx SO2
14 more results from this site ▶

Dillon Wood Boiler1 32 MMBtu/hr, 20, 000 tons/yr wood, 4400 Btu/lb, 550, 000 dscf/hr, 5500 hr/year at max capacity NOx SO2

www.anr.state.vt.us/air/permitting/PermitsTAs/TSDCersosimo.pdf

emissions = 59.3 ton/year assuming maximum operations 8760 hours per year. Total waste handling allowable PM emissions before modification = 59.3 tons per year ...
MMBtu/hr, 20, 000 tons/yr wood, 4400 Btu/lb, 550, 000 dscf/hr, 5500 hr/year at max capacity NOx SO2 Factor CO PM PM10 VOC HAP Permit #AOP-03-024 Allowable Emissions Emission Factor Units Source tons per year AP-42 Wood Residue Combustion in Lb/MMBtu ...
Total waste handling allowable PM emissions after modification = 44.9 + 8

Jan 2005 | Vermont Agency of Natural Resources – 14 more results from this site
Original Url: http://www.anr.state.vt.us/air/permitting/PermitsTAs/TSDCersosimo.pdf
Maximum Allowable Emission Rate (lbs/hr)
197 more results from this site ▶

Maximum Allowable Emission Rate (lbs/hr)

www.air.ky.gov/NR/rdonlyres/1C66080C-6883-4E7F-A855-612DCA36CF70/0/V08026Proposed_11910.pdf

Maximum Capacity (tons/hr) Maximum Allowable Emission Rate (lbs/hr) Emission Units Affected Facility 002 (1F01) 002 (1F02) 003 (RMF01) 003 (RMF02) 003 (RMF03) 005(HF01) 005(HF02) 005(HF03) 005(HF04) 005(HF04) 005(HF06) 005(HF07) 005(HF08 ...
d., below. [40 CFR 63.15053.(i)] i) 0.20 kg of PM per Mg (0.40 lb of PM per ton) of feed ...
40 lb of HCl per ton) of feed/charge or, if the furnace is equipped with an add

Jan 2010 | Division for Air Quality – 197 more results from this site
Original Url: http://www.air.ky.gov/NR/rdonlyres/1C66080C-6883-4E7F-A855-612DCA36CF70/0/V08026Proposed_11910.pdf
10 CSR 10-3.060 states that if the total equipment heat input has a capacity rating of ten (10) MMBtu or less, then the maximum allowable particulate emissions are limited to 0.60 pounds for each MMBtu/hr; or 3.3 lbs/MMBtu.
11 more results from this site ▶

10 CSR 10-3.060 states that if the total equipment heat input has a capacity rating of ten (10) MMBtu or less, then the maximum allowable particulate emissions are limited to 0.60 pounds for each ...

www.dnr.mo.gov/env/apcp/docs/biltbest-stegen-2006op.pdf

4 Emission Rate (lb/hr) Column 2 Column 3 Column 5 Column 6 Maximum Hourly Design Rate 0.0042 MMCF/hr 0.0003 MMCF/hr 0.001 MMCF/hr Heat Input (MMBtu/hr) Emission Rate (lb/MMBtu) Emission Factor 7.6 lb/MMCF 7.6 lb/MMCF 7.6 lb/MMCF Since these units ...
of Installation Heat Input (Q) Q Emission Unit Description Combined Space Heaters Powdercoat Burnoff Oven (Natural Gas-fired) Powdercoat Curing Oven (Natural Gas-fired) (MMBtu/hr) C) 10 CSR 10-6.260, Restriction of Emission of Sulfur Compounds Due to the nature

Jan 2004 | Missouri Department of Natural Resources - MoDNR – 11 more results from this site
Original Url: http://www.dnr.mo.gov/env/apcp/docs/biltbest-stegen-2006op.pdf
Sulfur Production Criteria Emission Rates During Periods of Emergency Emission Limits lb/hr
2699 more results from this site ▶

Sulfur Production Criteria Emission Rates During Periods of Emergency Emission Limits lb/hr

www.adeq.state.ar.us/ftproot/Pub/WebDatabases/PermitsOnline/Air/0762-AOP-R10.pdf

as referenced by §8-4-304 and §8-4-311] Table 10 – Sulfur Production Criteria Emission Rates During Periods of Emergency Emission Limits lb/hr Source Scenario Operating Limits Pollutant ...
Pilot Flame Deviation (<1200oF) * One-hour maximum emission rate. The 3-hour average ...
3-hour period (i.e., 7, 500 lb/hr on a 3-hour average). The records shall be updated

Apr 2007 | ADEQ - Arkansas Department of Environmental Quality – 2699 more results from this site
Original Url: http://www.adeq.state.ar.us/ftproot/Pub/WebDatabases/PermitsOnline/Air/0762-AOP-R10.pdf
Dated 1/95. Modified to Cooling Tower Design Emission Rate (lb/hr) = Water Circulation Rate (gpm) x 60 x Drift (%) / 100 x 8.3453 (lb/gal) x TDS (lb PM/1,000,000 lb water) x Weight Percent of Particle Size (%) / 100 Emission Rate (ton/yr) = Emission Rate (lb/hr) x 8,760 hr/yr / 2,000 lb/ton (f) Emission rate per cell = Emission rate total / Number of Cells
47 more results from this site ▶

Dated 1/95. Modified to Cooling Tower Design Emission Rate (lb/hr) = Water Circulation Rate (gpm) x 60 x Drift (%) / 100 x 8.3453 (lb/gal) x TDS (lb PM/1, 000, 000 lb water) x Weight Percent of Particle ...

www.deq.state.va.us/air/permitting/Dominion_Warren/Application/Vol_II_Application_Text_Mitsubishi.pdf

Emission Rate - Total Cooling Tower PM (e) (lb/hr) (ton/yr) (lb/hr) (ton/yr) (lb/hr) (ton/yr) 5.007E-02 2.193E-01 3.596E-02 1.575E-01 1.102E-04 4.825E-04 PM-10 PM-2.5 Emission Rate - Per Cell (f) PM (e) (lb/hr) (ton/yr) (lb/hr) (ton/yr) (lb ...
(e) Heater permitted to operate 8, 760 hr/yr (f) H2SO4 emissions based ...
Velocity Exhaust Flow Exhaust Temp ft ft ft/sec acfm F B-14 Water Circulation Rate

Apr 2010 | Virginia Department of Environmental Quality – 47 more results from this site
Original Url: http://www.deq.state.va.us/air/permitting/Dominion_Warren/Application/Vol_II_Application_Text_Mitsubishi.pdf
Following is a summary of the original proposed emissions in tons per year from the proposed Air Liquide hydrogen plant. The annual emissions were calculated for the average operating rate of 975 MMbtu/hr. The maximum daily emissions were calculated for the maximum operating rate of 1,072 MMbtu/hr.
48 more results from this site ▶

Following is a summary of the original proposed emissions in tons per year from the proposed Air Liquide hydrogen plant. The annual emissions were calculated for the average operating rate of 975 ...

hank.baaqmd.gov/pmt/title_v/B7419/B7419_2009-04_init_.03.pdf

emission factor is less than 0.0037 lb/MMbtu or by curtailing operations. The resulting ...
Summary of Hydrogen Plant Emissions Tons per Year Source NOx SO2 PM10 POC CO (975 MMBtu/hr, 34.2 annual average) New SMR Furnace Deaerator Vent Flare Pilots/NG Purge Startup/Shutdown Cooling Tower Fugitives Total ...
Phillips Refinery, Facility A0016, Rodeo CA Lb per Day Source Total NOx SO2 PM10 POC CO Air Liquide's final proposal is to reduce the particulate emissions from the new SMR

Jan 2007 | Bay Area Air Quality Management District - BAAQMD – 48 more results from this site
Original Url: http://hank.baaqmd.gov/pmt/title_v/B7419/B7419_2009-04_init_.03.pdf
Potential Emissions (lb/hr / tpy)
31 more results from this site ▶

Potential Emissions (lb/hr / tpy)

www.azdeq.gov/environ/air/permits/title_v/1001540/deqsupport.pdf

operations were calculated to be 46.5 lb/hr and 121 tons/year. HAP emissions ...
rates as follows: Toluene: 13.36 lb/hr and 34.75 tons/yr Methyl ethyl ketone: 11.74 lb/hr and 30.52 tons/yr Xylenes: 7.71 lb/hr and 20.05 tons/yr Methanol: 7.24 lb ...
Emission Point Name Potential Emissions (lb/hr / tpy) VOC PM10 SO2 NOX PM CO PB - 1 Package Boiler - 1 PB - 2 Package Boiler - 2 PB - 3 Package Boiler - 3 CRV - 1 Co-Ray

Jan 2002 | ADEQ: Arizona Department of Environmental Quality – 31 more results from this site
Original Url: http://www.azdeq.gov/environ/air/permits/title_v/1001540/deqsupport.pdf
Time SOX NOX VOC PM10 (hrs) (lb/hr) (lb/hr) (lb/hr) (lb/hr) (lb/hr)
653 more results from this site ▶

Time SOX NOX VOC PM10 (hrs) (lb/hr) (lb/hr) (lb/hr) (lb/hr) (lb/hr)

www.energy.ca.gov//sitingcases/colusa/documents/intervenors_others/2007-04-04_PRELIMINARY_DETERMINATION_COMPLIANCE.PDF

Commissioning Emissions Time SOX NOX VOC PM10 (hrs) (lb/hr) (lb/hr) (lb/hr) (lb/hr) (lb/hr) CO Unit Load Phase Tests CT # 2 100.0% 192.0 DB # 1 100.0% 192.0 DB ...
included in the table are based on a maximum non-emergency use rate of 50 hours ...
(pounds) NOX CO VOCs PM10 SO2 Annual Emissions (tons) NOX CO VOCs PM10 SO2 Firewater

Apr 2007 | California Energy Commission – 653 more results from this site
Original Url: http://www.energy.ca.gov//sitingcases/colusa/documents/intervenors_others/2007-04-04_PRELIMINARY_DETERMINATION_COMPLIANCE.PDF
◀ Prev 1 2 ··· Next ▶
Related searches: total criteria pollutant potential emissions, hourly criteria pollutant emission rates auxiliary equipment, oat hull & coal comparison, deferral analysis information pollutant baseline emission rate, total annual hap emissions

Hints & help

Language. English only please... for now.
Phrase search. You can use double quotes to make phrases (e.g. "mobile phones").
Booleans. You can use a plus ‘+’ to make a word mandatory, or a minus ‘–‘ to exclude it (e.g. +gas –oil production)
Vocabulary. We have only limited synonyms - please try different words in your query.
Questions? Please email us: helpdesk [at] zanran [dot] com
About Feedback PDF wizardry Twitter LinkedIn facebook Google+